摘要: |
建立了同时测定兽药复方磺胺间甲氧嘧啶预混剂中磺胺间甲氧嘧啶及甲氧苄啶含量的高效液相色谱法。以C18柱为固定相,0.1%磷酸溶液-乙腈(86:14)为流动相,流速为1.0mL/min,柱温40℃,检测波长为240nm,采用外标法进行定量。磺胺间甲氧嘧啶的线性范围为5.02~100.36μg/mL,回归方程为Area =0.62 × Amt-0.428 (n=5),r2=0.9996;甲氧苄啶的线性范围为1.01~20.28 μg/mL,回归方程为Area =1.058 × Amt-0.075,r2 = 0.9995。取复方磺胺间甲氧嘧啶预混剂,按磺胺间甲氧嘧啶和甲氧苄啶含量的100%作添加回收实验,分别作8个平行,测得磺胺间甲氧嘧啶的回收率为98.83%~101.95%,RSD为0.91%;甲氧苄啶的回收率为99.02%~103.09%,RSD为1.23%。该方法简单,准确,精密度好,回收率高,可以用于测量复方磺胺间甲氧嘧啶预混剂的含量。 |
关键词: 高效液相色谱法 复方磺胺间甲氧嘧啶预混剂 磺胺间甲氧嘧啶 甲氧苄啶 含量 |
DOI: |
投稿时间:2020-05-20修订日期:2020-11-20 |
基金项目:兽药国家标准制修订项目(2018H030) |
|
Simultaneous Determination of Sulfamonomethoxine and Trimethoprim in Compound Sulfamonomethoxine Premix by HPLC |
|
(Guizhou Provincial Supervisory Institute of Veterinary Drug and Feeds,Guiyang) |
Abstract: |
An HPLC method has been developed to determine the content of Sulfamonomethoxine and trimethoprim simultaneously in Compound Sulfamonomethoxine Premix, using C18 column as stationary phase, with a mobile phase of 0.1% phosphoric solution-acetonitrile (86:14) and wavelength of 240 nm. It was quantified by external standard method and the linear range of Sulfamonomethoxine was between 5.02 and 100.36μg/mL. And the regression equation was Area = 0.62 ×Amt-0.428 with the correlation to be more than 0.9996; the linear range of trimethoprim was between 1.01 and 20.28μg/mL, the regression equation was Area=1.058×Amt-0.075 with the correlation to be more than 0.9995. The average recoveries of Sulfamonomethoxine from eight spiked premix samples ranged between 98.83% and 101.95%, while relative recoveries of trimethoprim from that ranged between 99.02%~103.09% . This method was simple and accurate, and had good precision and high recoveries as well, could be used for determination of Sulfamonomethoxine and trimethoprim in Compound Sulfamonomethoxine Premix. |
Key words: HPLC Compound Sulfamonomethoxine Premix Sulfamonomethoxine Trimethoprim Content |