摘要: |
本研究通过制备可乐定完全抗原,免疫新西兰大白兔,得到特异性多克隆抗体,并和HRP标记的羊抗兔,构建间接ELISA检测法试剂盒,并进行性能测试评价。结果表明,吸光度百分比值与赛庚啶质量浓度的对数在0.1-8.1μg/L呈线性关系,相关系数R2为0.977,半数抑制浓度(IC50)为0.675μg/L,检测限为0.2μg/L,回收率为81% ~109%,具备良好的特异性,可用于动物尿样、血清和组织中的可乐定残留检测。 |
关键词: 可乐定,酶联免疫吸附测定,多克隆抗体,试剂盒 |
DOI: |
投稿时间:2017-01-28修订日期:2017-07-26 |
基金项目:国家公益性行业(农业)科研专项(201203023),上海市科技兴农重点攻关项目 [沪农科攻字(2014)第3-3号] |
|
Development and Performance Measurement of Clonidine ELISA Test kit |
|
(Shanghai Animal Disease Control Center) |
Abstract: |
An indirect competitive ELISA assay with preparing specific anti-clonidine polyclonal antibody was developed for the rapid detection of clonidine in the animal urine. The results showed that the logarithm of clonidine concentration with the absorbance percentage shows a linear relationship between 0.1~8.1 μg/L, the correlation coefficient R2 is 0.977, the half inhibitory concentration (IC50) is 0.675 μg/L, the detection limit for the clonidine assay is 0.159 μg/L, the sample recovery is 81%~109%, the variation coefficient is 3.7%~9.2%. This assay exhibits good specificity with no any cross reactions to β-agonists . It could be used as rapid detection for the residual clonidine in the samples such as animal urine, serum and tissues.. |
Key words: Clonidine Competitive ELISA Polyclonal antibody Test kit |