摘要: |
[摘 要] 采用紫外分光光度法和高效液相色谱法测定盐酸土霉素可溶性粉中土霉素的含量。紫外分光光度法试验表明,用0.01mol/L盐酸溶液作参比液,以268nm为测定波长,土霉素在4~32μg/mL范围内吸光度与浓度呈良好的线性关系,相关系数r = 0. 9999,平均回收率( n = 5)为101. 04%,RSD = 1.02%。高效液相色谱法试验表明,采用0.05mol/L草酸铵溶液-二甲基甲酰胺-0.2mol/L磷酸氢二铵溶液(75:20:5)为流动相,以280nm为检测波长,土霉素在0.02~0.14mg/mL范围内浓度与峰面积线性关系良好,相关系数r = 0. 9999,平均回收率( n = 5)为100. 52%,RSD = 0. 25%。紫外分光光度法、高效液相色谱法与抗生素微生物检定法比较,结果基本一致。 |
关键词: 紫外分光光度法 高效液相色谱法 盐酸土霉素可溶性粉 含量 |
DOI: |
投稿时间:2009-08-05修订日期:2009-08-13 |
基金项目: |
|
Determination of Oxytetracycline in Oxytetracycline Hydrochloride Soluble Powder by UV Spectrophotometry and HPLC |
liuxiaoyan |
(Guandong Dahuahong Animal Health Products Co., Plc,) |
Abstract: |
Abstract : UV spectrophotometry and HPLC method was developed for the assay of Oxytetracycline in Oxytetracycline Hydrochloride Soluble Powder. The UV Spectrophotometry results suggest that with 0.01mol/L hydrochloric acid as reference solution at 268 nm, the absorption of Oxytetracycline was in a good linear correlation( r = 0. 9999) with concentration in range of 4-32μg/mL, The average recovery was 101. 04% , and the RSD was 1.02% ( n = 5).The HPLC results suggest that with 0.05mol/L ammonium oxalate-Dimethyformamide-0.2mol/L ammonium phosphatedi basic as mobile phase and detectingwavelength of 280 nm ,the Oxytetracycline presented a good linear relationship ( r = 0. 9999) within the range of 0.02~0.14μg/mL, the average recovery was100.52%, and the RSD was 0.25% ( n = 5). UV Spectrophotometry , HPLC and antibiotics-microbial test , the results are basically the same. |
Key words: UV Spectrophotometry HPLC Oxytetracycline Hydrochloride Soluble Powder content |