引用本文
  •    [点击复制]
  •    [点击复制]
【打印本页】 【下载PDF全文】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 2032次   下载 1 本文二维码信息
码上扫一扫!
高效液相色谱法测定饲料中喹乙醇含量
宫秀杰
0
(新疆兽药饲料监察所)
摘要:
利用高效液相色谱法测定饲料中喹乙醇含量。采用C18色谱柱,以0. 02mol/L磷酸‐甲醇(85:15)为流动相,流速为0.8mL/min,检测波长为380nm。喹乙醇在0.1µg/mL-100µg/mL范围内线性关系良好,r=0.999904;经5种不同浓度回收率的测定,其回收率在85.5%‐93.6%之间,RSD 小于5.2(n=5)。
关键词:  高效液相色谱法  喹乙醇  饲料  含量
DOI:
投稿时间:2008-04-15修订日期:2008-05-07
基金项目:
Determination of the Olaquindox in feedstuff by HPLC
gongxiujie
(Xinjiang Institute for Verterinary Drugs and Feedstuff control)
Abstract:
A method of HPLC was used for determination of olaquindox content in feedstuff.A C18 column was used with the mobile phase consisted of 0.02mol/L phosphatic‐methanol(85:15),the flow rate was 0.8mL/min,the detection wavelength was 380nm.The calibration curve was linear at a range of 0.1~100µg/mL for the olaquindox (r=0.999904).The recoveries of olaquindoxv added to blank feedstuff at levels of five concentrations were between85.5% and93.6%(n=5).
Key words:  HPLC  olaquindox  feedstuff  content

用微信扫一扫

用微信扫一扫